PoE Power Budget for IP Cameras: How to Check a Switch Before You Buy

How to add up Power over Ethernet demand for IP cameras and PTZ units, why the switch budget is not the sum of what cameras use, and a worked example for a 32 camera site.

Shruti IT Service Engineering Team

Survey, design and maintenance engineers, Nashik

Published On

16 Nov 2026

Read Time

7 min read
Share Guide:
IP cameras and network switch cabling for a CCTV installation

A switch sold as 48 ports with PoE does not power 48 cameras. It powers as many as its total PoE budget allows, and that figure is often much smaller than the number of ports suggests. Buyers discover this after installation, when the last cameras on the switch refuse to start. A five minute calculation before ordering avoids it.

Key Engineering Takeaways

  • The switch budget is a total in watts for all ports together, not a per port promise.
  • PoE standards define power at the switch port and power available at the device, and the device gets less because of cable loss.
  • Many switches reserve power by device class, not by what the camera actually draws.
  • Keep total allocation under about 80 percent of the budget to leave room for growth and heat.

What the standards give you

Three PoE standards cover most cameras. IEEE 802.3af, often called PoE, supplies up to 15.4 W at the switch port and guarantees 12.95 W at the camera. IEEE 802.3at, called PoE+, supplies up to 30 W and guarantees 25.5 W at the device. IEEE 802.3bt, sometimes called PoE++, supplies 60 W or 90 W and is used for heavy PTZ units with heaters and for some access points.

The difference between port power and device power is lost as heat in the cable. A camera that says it needs 12 W is inside the 802.3af limit, but one that needs 14 W is not, even though 14 is below the 15.4 W figure.

Worked example: 32 cameras

Take a 32 camera site with 24 fixed 4 megapixel cameras that draw 8 W each, and 8 PTZ cameras that draw 25 W each. The real draw is 24 x 8 = 192 W plus 8 x 25 = 200 W, a total of 392 W. A quick sum would say a 740 W switch has plenty of room.

Now see how the switch actually allocates. Many switches reserve power by the class the camera announces. The fixed cameras announce class 3, which reserves 15.4 W each: 24 x 15.4 = 369.6 W. The PTZ units need class 4, which reserves 30 W each: 8 x 30 = 240 W. The reserved total is 609.6 W, which is 82 percent of a 740 W budget.

Reservation can be several times higher than real use. The switch counts what it set aside, not what the camera draws, unless it supports dynamic allocation using LLDP. Check the datasheet or the management screen.

What to do with that result

At 82 percent the design is over the 80 percent target, and it leaves little space for the next camera. There are three clean options. Choose a switch with a larger budget. Split the load over two switches, which also limits what a single switch failure takes down. Or move the PTZ units to a separate 802.3at switch and keep the fixed cameras on a smaller one.

Splitting is often the better answer for reliability. If one switch with 32 cameras fails, the whole site goes dark. With two 16 camera switches half of the site stays up.

Cable and distance

PoE works over copper Ethernet cable up to 100 metres from switch to camera, counting patch cords. Beyond that, use a fiber link and a media converter or an industrial switch near the camera. Solid copper Cat6 cable carries PoE with less loss than copper clad aluminium, and the cheap aluminium cable sold for CCTV is a common cause of cameras that reboot under load.

In a bundle of many cables, heat builds up and resistance rises. For long runs and high power devices, use thicker cable or lower the number of cables bundled together.

Checks before you order

  • Write down every powered device with its real wattage and its PoE class.
  • Calculate the reserved total using the class figures, then compare it to the switch budget.
  • Confirm whether the switch allocates by class or by measured draw.
  • Confirm the uplink speed: 32 cameras at 4 Mbps send 128 Mbps, which is well within a gigabit uplink but worth stating.
  • Keep a spare port or two on each switch for maintenance and replacement.

Conclusion & Next Steps

Treat the PoE budget as seriously as the storage calculation. Ask your supplier for the device list, the reserved power by class, the switch budget and the margin left. We include that table in every camera design we prepare, so you can check it yourself.