Every fiber link loses some light on the way from the transmitter to the receiver. The receiver can only work if enough light arrives. A loss budget is the sum of everything that eats light, compared with what the optics can tolerate. Doing this sum before you order cable and optics prevents the unpleasant case where the link is built and will not come up.

Key Engineering Takeaways

  • Total loss is fiber loss plus connector loss plus splice loss plus a safety margin.
  • Use the cable datasheet for attenuation, and conservative values for connectors and splices.
  • Compare the total with the optics' rated channel loss, and watch for receivers that are overloaded on short links.
  • Measure the finished link with a light source and power meter, and keep the OTDR traces for fault finding later.

What eats light

Three things take light out of a link. The glass itself loses a little for every kilometre. Each connector pair loses a little where two ends meet. Each fusion splice loses a very small amount where two fibers are joined. Bends, dirt on connectors and poor splices add more, and good installation keeps them small.

Planning values you can start from

These are common planning values for single mode fiber. Use the figures in your cable and connector datasheets where they exist, and treat the rest as assumptions.

  • Fiber attenuation: about 0.35 dB per kilometre at 1310 nm and about 0.25 dB per kilometre at 1550 nm for typical outdoor cable.
  • Connector pair: about 0.5 dB as a conservative allowance, though good connectors measure lower.
  • Fusion splice: about 0.1 dB as a planning figure.
  • Margin: 3 dB or more for repairs, ageing and measurement uncertainty.

Worked example: an 18 km link at 1310 nm

The route is 18 kilometres of cable in drums of about 2 kilometres, with a patch panel connection at each end. That means 2 connector pairs and about 8 splices along the route.

Fiber loss: 18 x 0.35 = 6.3 dB. Connector loss: 2 x 0.5 = 1.0 dB. Splice loss: 8 x 0.1 = 0.8 dB. The expected loss is 8.1 dB. Add a 3 dB margin and the design budget is 11.1 dB.

In this example a standard 10 km class optic, which tolerates about 6 dB of channel loss, would not work. A 40 km class optic, rated for roughly 11 dB, just fits with the margin intact. Always check the optic's datasheet for the exact figure.

Do not forget the other end of the range

Long range optics send a lot of power. On a very short link the receiver can be overloaded, and the link fails or shows errors. In those cases a fixed attenuator may be needed. The optic datasheet gives the minimum and maximum receive power, and a good design checks both.

Testing at handover

Test the finished link in two ways. A light source and power meter test measures the end to end loss, which is the number that decides whether the optics work. An OTDR test draws a picture of the link, showing each splice, connector and bend as an event along the distance. Testing in both directions and averaging gives a fairer splice loss than a single direction.

Ask for the results as files and as a table: the route, the length, the loss at each wavelength and the individual event losses. Keep the OTDR traces. When the link is cut one day, a trace taken at handover lets a repair team find the break by comparing.

Conclusion & Next Steps

A loss budget takes ten minutes and saves weeks. Ask for it in the design, ask for the tested result at handover, and compare the two. Our fiber engineers prepare route surveys, loss budgets, splicing records and test certificates so that the link you receive matches the link that was designed.